Description

Overview
Lantern control panel for TEF 2850 lanterns.
230 (115) volt system

Technical Data

Material Aluminium. Black anodised front
Power supply 2 x 230V AC (2 x 115V AC)
Max power consumption 800W (9 circuits) - 1150W (13 circuits) - 1400W (16 circuits)
Load Filament lamps 230V (115V), max. 85W
Fuses Ceramic 5 x 20mm, 4 AF Located in terminal box
Dimensions (wxhxd) 144 x 384 x 150mm
Weight Max 5,5 kg.
Cut-out 124 x 364mm

Applications

For single tier lanterns
For control, monitoring and fusing of all kinds of 230V (115V) lanterns
Offered in three different sizes: for 9, 13 and 16 lanterns
Offered for flush mounting or in cabinet for bulk mounting

Features

Engraved text specified by customer. Front plate is easily exchengeable
Easy installation. The terminals are separated from the control box by a 1-meter flexible conduit. (Flush mounting version only)
Automatic power supply selector, with priority on main supply. Alarm when a supply is missing
Acoustic and visible alarm when failure in lantern circuit.
Potential free contact set for remote monitoring of alarms
Test button for indicator LED’s and alarm circuit
Two pole switches