OverviewLIQUANTY liquid counters are precision flow and consumption meters for non‑aggressive liquids with a kinematic viscosity range from 0.5 to 3000 mm²/s (cSt). The product family includes Gear (oval‑gear), Ring (ring‑piston) and Corio (Coriolis) series, covering applications in power generation, marine, petrochemical, industrial and municipal sectors. Units operate autonomously or integrate into automation, telematics and IIoT systems.
Key functions and benefits- Accurate measurement of volumetric and, for Corio, mass flow (examples: volume ±0.21% / mass ±0.16% for diesel in Corio range)
- Wide viscosity compatibility across series (from ~0.5 to 3000 cSt depending on model)
- Model range covering flow rates from 0.33 to 6700 L/min
- Local real‑time display and data outputs for recording and telematics
- Integration interfaces: CAN J1939, pulse outputs, RS‑485/Modbus RTU, Bluetooth Low Energy, ± options
- Versions with built‑in battery for autonomous operation and data logging
ModelsLIQUANTY GearOval‑gear meters for stationary installations and auxiliary ship equipment.
- Applications: light petroleum products (diesel, heating oil), non‑aggressive fuel additives; measurement of distributed volumes and total consumption, operating time recording
- Typical features: oval‑gear measuring chamber; informative digital display with multiple counters; integrated battery for autonomous use; interfaces: CAN J1939, pulse, Bluetooth LE; RS‑485 via optional converter
LIQUANTY Gear — Selected specification linesModels: LIQUANTY Gear 120 / LIQUANTY Gear 410
Minimum flow: 12 L/min / 41 L/min
Maximum flow: 120 L/min / 416 L/min
Relative error (max): 0.25%
Calibrated viscosity range: from 0.55 to 300 cSt
Maximum liquid temperature: 90 °C
Maximum working pressure: 1.6 MPa
Interfaces: CAN J1939, pulse, RS‑485 (optional converter)
Ingress protection: IP54 (IP67 on request)
Connections: Gear 120 — flanged, threaded; Gear 410 — flanged
Weight (max): Gear 120 — 5.4 kg; Gear 410 — 14.6 kg
LIQUANTY RingRing‑piston meters for heavy‑duty land and rail machinery and small vessels.
- Applications: diesel and heating oil metering for heavy vehicles, mining equipment, shunting locomotives, tugs and small/medium vessels, gensets and boilers
- Design highlights: simple, reliable ring chamber; digital display with multiple parameter screens and counters; built‑in battery; available autonomous, wired (CAN, Modbus, pulse) and wireless (BLE) models
LIQUANTY Ring — Selected specification linesModels: LIQUANTY Ring 15 / 30 / 65
Minimum flow: 0.33 / 0.66 / 1.33 L/min
Maximum flow: 16.5 / 33.0 / 66.0 L/min
Relative error (max): ≤ 0.5%
Viscosity range: from 1.5 to 6.0 cSt
Maximum liquid temperature: 95 °C
Maximum working pressure: 25 bar (flanged) / 16 bar (threaded)
Interfaces: autonomous; CAN J1939; pulse; wireless (Bluetooth)
Connections: flanged or threaded
Weight (max): Ring 15 — 4.3 kg; Ring 30 — 6.3 kg; Ring 65 — 9.3 kg
LIQUANTY CorioCoriolis meters for mass and volumetric measurement in marine and industrial pipelines — near‑zero flow resistance and direct mass measurement.
- Applications: marine fuel oil, technical water and other non‑aggressive liquids for large vessels, industrial pipelines, fuel dispensing systems and diesel power plants
- Design highlights: simultaneous mass and volume measurement; stable under vibration and temperature/pressure fluctuations; suitable for high‑viscosity liquids; low maintenance; wide nominal diameters
LIQUANTY Corio — Selected specification linesExamples of models and volumetric ranges: Corio 95 — 7–100 L/min (DN 15); Corio 380 — 25–380 L/min (DN 25); Corio 1200 — 77–1240 L/min (DN 50); Corio 2300 — 192–2300 L/min (DN 80); Corio 3800 — 514–3800 L/min (DN 100); Corio 6700 — 575–6700 L/min (DN 150)
Liquid temperature range: −60 to +100 °C
Operating pressure range: 0 to 4 MPa (model dependent)
Accuracy (diesel): volume ±0.21% / mass ±0.16% (indicative)
Output interface example: RS‑485 (Modbus RTU)
Pipeline connection: flanged
Data available on display and outputs- Total liquid consumption (volume and/or mass)
- Total operating time of the counter
- Consumption and operating time by operating modes (e.g., idle, normal, overload)
- Clearable consumption and operating time counters
- Temperature in measuring chamber
- Battery charge percentage and runtime parameters
- Mass flow and volume flow (Corio); liquid density (Corio)
Technical characteristics- Product family: LIQUANTY Gear, Ring, Corio
- Measured parameters: volumetric flow, mass flow (Coriolis), temperature, density, operating time, counters by mode
- Flow coverage: 0.33 L/min to 6700 L/min across models
- Viscosity ranges: Ring ~1.5–6 cSt; Gear ~0.55–300 cSt; Corio ~0.5–3000 cSt
- Temperature ranges: Gear up to +90 °C; Ring up to +95 °C; Corio −60 to +100 °C (model dependent)
- Pressure capabilities: Gear up to 1.6 MPa; Ring up to 25 bar (flanged) / 16 bar (threaded); Corio up to ~4 MPa
- Accuracy examples: Gear ~0.25%; Ring ≤0.5%; Corio ~±0.21% (volume) / ±0.16% (mass) for diesel (indicative)
- Interfaces: CAN J1939, pulse outputs, RS‑485/Modbus RTU, Bluetooth Low Energy; some autonomous battery versions
- Ingress protection: IP54 standard; IP67 available on request for some models
- Connection types: flanged and/or threaded