INTEGRATED OR STAND ALONE
The system is designed for level gauging in ballast and service tanks. It can be interfaced to an Integrated Automation System or operate as a stand-alone system. All system components are designed and manufactured to work in a rugged marine environment. The system is type approved by all major classification societies.
KEY FEATURES
Individual level sensors, based upon rugged and accurate pressure transmitters made in titanium
Level and volume presentation
Standard corrections for vessel trim and list
Atmospheric pressure correction as standard for installations with submerged level sensors
Easy and inexpensive installation /refit
At site configuration, simple alarm setting (level - high or low) and liquid density parameter setting
Easy manual settings of specific sensor inputs in case of sensor failures
Internal alarm buzzer and output for other alarm devices
Delivered with 220/24V power supply as standard
OPTIONS
Our ballast and service tank gauging system has a flexible design and can be offered with the following optional features:
Serial interface to other presentation systems or load calculator. The serial interface is RS232 or RS485 and is based on MODBUS protocol.
Cabinet for wall mounting including power supply, zener-barriers, termination, etc.
Monitoring of tank temperatures and miscellaneous pressures
Inclinometer for trim and list
Draft measurements