TLG


electronic pressure transducers type G1, ceramic sensor cell, delivered ready calibrated to the pressure height, calculated from tank height minus tank offset, multiplied with given density of the tank medium. Adaptation to changing specific weight and/or tank offset are not possible when once defined.

-Exactitude: better 0,2 % FR, at least

- Overpressure: at least 4 bar overpressure safe, Temperature range: valve body 25 ... + 85 °C, membrane --40 ... 125 °C

-Materials: membrane AL2 O3, body stainless steel 1.4305

- Connections: dry installation flange DN 25, PN16 submerged installation guided inside supporting pipe.

- Electric connection: two-wire-system, supply 24 V DC, 11- 32V

- Output: analogue 4 - 20 mA

- Protection degree: IP68 for dry and submerged installation

-Recommendation: submerged installed sensors should be accessible or removable without entering into the tank.