- Hold-ventilation systems incl. Explosion proof execution
- Tank-ventilation systems. incl. Explosion proof execution
- Engine-Room ventilation systems
- Sanitairy exhaust systems
- Welding-foam exhaust systems
|
|
This is a single duct air supply unit designed for ceiling mounting above the false ceiling. Intended for climate control in spaces on board ships, such as cabins, offices, messes, utility spaces etc.
- Provides good thermal comfort.
- Offers individual temperature control of both supply air temperature and air flow.
- Available for manual or automatic control by means of a pneumatic or electrical actuator.
- Offers quick and simple installation and commissioning.
- The internal insulation satisfies the criteria of IMO Resolution for classification as non-combustible.
- Conforms to the provisions of IMO Resolution for false ceilings with fire resistance rating B15.
- Satisfies the vibration and temperature requirements specified by Det Norske Veritas.
|
|
|
Fan coil units can be applied when cooling or heating is required. This unit can be easily installed in the compartment without being entirely visible. It is possible to install several in the same compartment. This way the capacity is increased or can be dispersed without any problem. Included with this system are all standard items that are required for mounting and installing the unit. Fan coil units can be perfectly combined with all our existing systems.
|
|
FEATURES
Horizontal Type, ceiling mounted 530N Fan Coil Units provide high capacity local cooling/heating.
- Shock tested to MIL-S-901D
- High performance
- Compact Unit
- Completely prepackaged
- Units are completely tested on performance according to ARI 440-98and ASHRAE 79-91
- Factory tested
- Low weight
- Left /Right hand connections
- Electric /Hot Water Heating
- Low structure borne noise levels allow the unit to be hard mounted to the ships structure
|
|
|
Approved by GL, BV, DNV, LRS, ABS, RS, energy-efficient and environment-friendly, designed to DIN EN 60034 (IEC 72), mounting dimensions and assignment of output ratings to DIN 42673, 42677 or progressive, robust low-vibration grey cast iron design, degree of protection IP 55, higher degrees up to IP 65 on request, class F insulation with thermal reserve, class H available as an option, terminal box optionally top-mounted, RHS or LHS, various modifications possible
|
|
- Portable or wall mounted low-noise fan heater
- Designed to meet applicable marine requirements
- Type approved
Specifications:
- Wall mounted or portable fan heater for marine and offshore applications.
- Corrosion resistant housing of hot zinc-plated and powder coated steel panels.
- Re-setable overheat protection.
- Low noice fan.
|
|
VMA-VMB
These air heaters are integrated units with axial flow fans and heating coils. Two versions are available, depending on the heat media being either boiler water or district heating water.
|
|
FEATURES
SMOKE DAMPERS
Class I meets UL 555S.
Class 1A smoke dampers in both vertical and horizontal mountings.
FIRE DAMPERS
For shipboard installation of A0 thru A60 fire rated divisions in both vertical and horizontal mountings. Meets FTPC Part 3, IMO Resolution A754 (18).
IMPORTANT
Type, tested and approved damper assembly does not constitute ships installation and configuration approval, which is subject to governing authorities regulations.
The fire dampers are designed for dry filtered air systems and should be subjected to the maintenance program.
|
|
|
Tailor made Accommodation Heaters provide the optimal indoor climate for personel and equipment. The heaters are provided and designed according to Customers request.
|
|
- Oil-fired boilers (incl. GL- or LROS- approval and alarming) incl. burner (on Gas-oil or MDO)
- CH-systems on heat-exchanger for Thermical-oil.
- Air-heaters on hot-wate
- Air-heaters on Thermical-oil.
- Heat-recovery from main-engine coolingwater.
- Heat-recovery from main-engine Exhaust-gasses.
- Radiators.
- Pumps.
- Expansion-vessels
- Appendages.
|
|
|
Marine use packaged type air conditioner is designed in consideration of special conditions on board ship. These units are executed in a high-quality finish and specially designed for placing in both accommodation areas and technical spaces
|
|
Jamestown will design, supply and install complete HVAC systems for any marine product. Our HVAC group has over 100 years of marine and industrial experience and uses this knowledge to the benefit of all projects. We incorporate equipment and components from major HVAC suppliers as well as those that may be selected by our customer.
Synergy %u2013 By choosing Jamestown for both HVAC and joiner installation, many of the typical onboard installation schedule interferences are resolved.
Component Coordination %u2013 We manufacture our own duct work to your specific requirements and coordinate its delivery to the construction site, as well as all refrigeration and ventilation equipment.
Complete responsibility %u2013 We will design, supply, install, test and balance the HVAC system.
|
|
Navy system 1
Navy projects can cover anything from almost merchant ship standards to specialised systems with demanding equipment and system requirements. Each project is individually evaluated with regard to necessary custom solutions.
|
|
|
Refrigerating technology has been an indispensable precondition in the constant improvement of living conditions on board. Without this it would not be possible to provide a balanced and healthy environment in comfortable living quarters with a controlled and pleasant climate.
|
|
Complete factory assembled
Open type compressor
Designed for marine use
Environmental friendly refrigerants
Custom produced
|
|
|
|
|
|
|
ALMACO offers a leading choice of Compressor Units, Air Coolers and Electronic Control Systems for Newbuilding and Modernization projects for cruise ships, ferries, accommodation vessels and offshore accommodation platforms. Wide range of refrigeration machinery, flexible design and a choice of compressors are few of the benefits of ALMACO’s Refrigeration Machinery leadership in the marine industry.
High quality condensing units and brine chillers meet the stringent demands set by the marine environment. Some of the main characteristics are:
Units based on screw or piston compressors of either open or semi-hermetic type
Integrated, compact units allow for easy installation, servicing, and optimal space utilizations.
Air coolers are designed in accordance with USPHS requirements.
All refrigeration machinery equipped with Cool Control, a powerful control and monitoring system to manage provisions stores temperature control, the air cooler defrosting sequence, and alarms.
Complete customization to fit customer’s individual needs, including lay-outs, food production calculations, cost comparisons between alternatives, and technical specification of all equipment
The complete Refrigeration Machinery solutions ALMACO offers incorporate:
Planning
Design & Engineering
Installation
Commissioning
Sea trials: everything from the first cooling capacity calculations to the final test reports and crew training to achieve the highest performance and reliability on the market.
After Sales, Spares & Equipment
ALMACO refrigeration systems have been selected as first class technology for the world’s largest ships Queen Mary II and the Genesis project.
|
|
Square closing dampers.
Manual & Pneumatic operated types are available with multi-blade design.
|
|
SJD
These louvre dampers are used for regulation and mixing of air flows in ventilation systems and other air handling installations.
|
|
Design features:
- Self contained return air cooling units for marine and offshore application
- Standard refrigerants R134a and 404a
- Electrical power supply 50/60 Hz
- Operating panel with mode switch for cooling – heating (option) – ventilation
- Temperature controller with digital temperature indication
- Easy maintenance and service
- Up to date compressor technology
|
|
NovPac-R
The self-contained air handling units type NovPac-R are compact and designed for supplying air conditioning in rooms such as engine control rooms, switchboard rooms, workshops etc.
|
|