|
|
The Alarm and Control System ACS-1 is a versatile control system for use in "Fixed Water Based Local Application Fire Fighting Systems" (FWBLAFFS) according IMO MSC/Circ.913 with integrated fire detection. It can also be used in other areas as a stand alone fire detection system, as a Sprinkler alarm system or as engine room protection system. Due to its flexibility it can also be used in other fire detection and extinguishing plants.
* standardized system, simple to install
* simple operation
* safe operation due to special false release protection
* use of bus system reduces cable work
* very compact dimensions ease planning and mounting of the system
* controls up to 32 sections
|
|
Consilium’s Salwico CS4000 fire alarm system is a fully adaptive analogue addressable system. In an alarm situation it can easily identify the unit that has given the alarm and is therefore capable of giving correct information about the exact location of the fire at a very early stage
The Salwico CS4000 offers extremely reliable fire detection with a high degree of protection against unwanted alarms. Every loop unit in the CS4000 has a built-in intelligence and can initiate a fire alarm all by itself.
The Salwico CS4000 is designed and developed to meet with the demands of all major classification societies, the EN-45 rules and the new European standard MED. The system is very user-friendly with a self-instructing control panel, which with clear and easily understood instructions on the display, leads the operator through the various functions.
|
|
CS/Syncro ASM is the analogue addressable control panel homologated marine with requirements EN54-2:1997 e EN54-4:1997.
The control panel which can boast various classifications can provide a measured and cheap solution for all small to medium sized vessels and can be interfaced with a monitoring, control and supervising system.
Available with 1 or 2 loops is capable of covering a maximum of 16 zones with 126 fire detection devices on each loop.
|
|
We offer conventional fire detection systems for minor installations.
Our standard BX-10 system is especially suitable for day-care centres, schools, smaller stores, industrial buildings, smaller overnight stops and farm buildings, plus automatic and distant telecommunication installations.
The BX-10M1 fire alarm control panel is a modern conventional unit designed for minor maritime installations. Among applications, the BX-10M1 is especially suitable for fishing boats, yachts and smaller cargo ships.
BX-10 - smaller installations
BX-10M1 - smaller maritime installations
|
|
Autronica Fire and Security has developed the world's first interactive-addressable system for integrated fire and gas detection: AutroSafe Integrated Fire and Gas Detection System (IFG), the only integrated fire and gas detection system that is approved according to IEC 61508 Safety Integrity Level 2 (SIL2).
AutroSafe IFG has been developed in close collaboration with the petrochemical, oil and gas industry. AutroSafe IFG is designed to comply with present and future standards, including EN 54, and is approved by many international standards organizations
|
|
In developing the Salwico GS3000 we have used the experiences and hardware from our proven and trusted fire detection system, the Salwico CS3000 and adapted these to gas detection requirements found in offshore applications, onboard LNG carriers and other demanding installations.
Un-rivalled still today the Salwico GS3000 is by far the most dependable loop-configured analogue addressable gas detection system in the world and it offers all the features and functions of the larger Fire Detection System and then we added some more to cover for the gas detection needs specifically.
|
|
Consilium offers the world’s only true continuous measuring NOX, SO2 and CO2 analysing equipment for marine applications.
Salwico NOx & SO2 Analyzing System
The Salwico Emission Monitoring System is the world’s only true continuous measuring NOx, SO2 and CO2 analysing equipment for marine applications. The system, fully type approved by Lloyds Register (certificate number 07/00043), measures emissions of Oxides of Nitrogen (NOx), Sulphur Dioxide (SO2) and the greenhouse gas CO2 from the engine exhaust of marine diesel engines.
Salwico NOx & SO2 Analyzing System is a continuous measuring and analysing equipment for marine applications. Unlike other competitors non-compliant solutions based on electrochemical sensor technology our analyzing technology is based on the regulatory chemiluminescent principle as stated in the “Marpol Annex VI NOx Technical Code”
|
|
Accommodation Air Conditioning Inlet Gas Detection
The new fifth edition of ISGOTT now identifies the advantage of fitting flammable gas detection at accommodation air conditioning inlet. MM2000® is an intelligent addressable gas detection system that is ideally suited to this duty with duct mounted flammable gas detectors simply mounted on the inlet and the control panel located in the cargo control room (CCR).
The addressable sensors are installed on a single four-core loop cable that saves installation costs when multiple inlets are to be monitored, for monitoring general accommodation areas and hydrogen sulphide / hydrocarbon gas detection in the cargo pump room.
In total, the system can monitor 32 individual gas detectors meaning most applications can be serviced by one compact MM2000® control panel.
|
|
|
|
|
|
|
Ballast Tank Gas Detection & Void Space Gas Detection System
MM5001® is a major advancement in marine gas detector technology for monitoring ballast tank gas detection and void space gas detection onboard ships. The system comprises of a central control cabinet with a touch screen panel to display information and alarm status. Within the cabinet is the main PLC controller, analysing equipment plus a pre-sampling circuit as standard. A calibration free, high performance infrared sensor provides the ultimate in reliable flammable gas analysis.
The PLC is extremely reliable with an MTBF of 20 years plus. The gas analyser does not require re-calibration and the pre-purge significantly reduces sampling cycle times.
MM5001® is fully compliant with IACS UR F43, Exxon MOBIL MESC 2002 - Term charter, Chapter 8 & EMSA regulations for double hulled tankers.
- CALIBRATION FREE, HIGH PERFORMANCE IR SENSORS
- FULLY FLEXIBLE PLC CONTROLLER
- PROGRAMMABLE OPERATION DURING BALLASTING
- INTEGRATED SYSTEM FOR BOTH GAS SAMPLING & FIXED POINT SENSORS
|
|
Refrigerant Gas Leak Detection
MM2000® is an intelligent addressable gas detection system designed to provide refrigerant gas detection on ships under MARPOL Annex VI Regulation 12-Ozone Depleting Substances, 5.5 Leak Monitoring Systems.
Refrigerant gases are monitored continuously by fixed gas sensors installed in the vicinity of refrigeration and air conditioning machinery such as compressor room refrigerant leak detection. Class societies advocate the use of fixed leak detection systems for environmental protection (e.g. Lloyds EP Notation) The MM2000® system operates on a single 4-core cable having the capacity to monitor from 1 to 32 addressable sensors.
The control system provides local indication of the measured parameters and alarm conditions together with relay contacts to shut down air conditioning or refrigeration plants as necessary.
- TYPE APPROVED
- LOOP SENSOR CABLE FOR LOW COST INSTALLATION
- NO MOVING PARTS
- CONTINUOUS MONITORING OF ALL LOCATIONS
|
|
|
The Smoke Detection System SDS-48 is the successor of the SDS-2/6. From the SDS-2/6 it has inherited the same simplicity of installation and operation, but it requires up to 50% less space for installation. Even more flexible than its predecessor SDS-2/6, the Smoke Detection System SDS-48 allows for a maximum of 48 detection lines. It complies with FSS Code Chapter 10.
|
|
|
With more than 1000 installed systems, the SDS-2/6 is one of the most successful Smoke Detection Systems for cargo vessels in the last years. It is a modular system for up to 36 detection lines. It complies with SOLAS Chapter II-2 Regulation 13-1.
|
|
In an emergency, people must not only be able to hear an alarm - but understand its message. Autronica's voice alarm avoids the use of confusing and often frightening emergency bells or sirens. Our voice alarm uses a public address system (PA) to tell the public what the emergency is, where it is, and what to do. A calm, authoritative voice - either a prerecorded message or, when necessary, a live announcement, gives the public clear and informative instructions.
People are able to distinguish immediately between fire drills or tests and a real emergency situation. In case of a fire breakout, the public can be directed safely to specific exits, away from danger areas. Integrated into an Autronica fire detection system with point detectors and aspirating detectors, you will achieve the safest and most reliable solution in shopping centres - allowing the fastest evacuation in an emergency situation.
|
|
| ... products without information |
| |
|
|