MARINE AIR HANDLING UNIT FEATURES
- Insulation thickness 2" or 4"
- Self supporting steel base, ready for deck installation
- Mixing section complete with opposed blade, fresh and return air dampers
- High or medium efficiency filters
- Direct expansion or chilled water cooling coils
- Electric, hot water or steam heating coils
- Electric control panel mounted on the unit complete with all necessary climatic and safety controls
- High performance centrifugal fan enclosed in the units fan section, resiliently mounted with safety screen
|
|
Climaster ZCP
The Climaster ZCP air handling units are flexible and individually designed units primarily for the marine market and for some land applications. Common to all usage areas is the demand for a tough and robust unit capable of meeting very diverse requirements.
|
|
|
|
|
|
|
FEATURES
Marine grade axial fans manufactured under license from Witt & Sohn are available for standard and high pressure applications.
Witt & Sohns well proven expertise has established this product as one of the leaders in Marine fan technology and associated noise and vibration control.
With a standar fan design as the starting point for a given application, using the latest CAD technology the Witt design team can rapidly incorporate any requisite design modifications from standard component elements to accommodate even the most exacting fan specification.
This means that such specification criteria (eg. severity of duty; space limitations; special materials and surface treatments) - can be incorporated efficiently and at considerably less cost and lead time than a conventional one off design approach
CONSTRUCTION
AXIAL - FLOW FANS
- Inlet Sizes - 250 to 2800 mm.
- Casing Thickness - 1,5 to 16 mm.
- Impeller Types - N, M, X, Y, H (adj. Pitch)
- Motor Frame Sizes - NEMA or IEC
- Drive Types - Direct, V-belt or coupling
- From Positions - See attached to Positions as requested
- Casing Designs - Short/long casing, swing out, w/wo shaped inlet
- Surface Treatment - Primer; finish; hot-dip galvanized, as required
- Materials - Corrosion resistant cast Impellers Aluminum
- Materials - Steel, aluminum, special Casings Alloys
- Special Designs - Flame-proof; shock-proof; high temperature, as required
|
|
ACN
The Novax ACN axial flow fans have pre-settable blades and are for duct installation and suitable for both conventional installations for marine and for industrial ventilating applications.
|
|
AXIAL-FLOW FANS
nlet sizes 250 to 2800 mm.
Casing thickness 1,5 to 16mm.
Impeller types N, M, X, Y (adj.pitch).
Motor frame sizes 63 to 400.
Drive types Direct, V-belt or coupling.
Positions A,AU,AD,B,BD,BU (Eurovent).
Casing designs Short/long casing, swing out, w/wo shaped inlet.
Surface treatment Primer; finish; hot-dip galvanised, as required.
Materials - Impellers Corrosion resistant cast aluminium.
Materials - Casings Steel, aluminium, special alloys.
Special designs Flame-proof; shock-proof; earth-quake proof; high temperature, as required.
|
|
Axial fan, high efficiency (-83%), blades adjustable when stationary, direct drive, medium pressure fan
Surface: hot-dip galvanized or powder coated
Options: pully belt drive, ATEX, various accessories
Sizes:
VML 500 - VML 2.000 (Ømm)
Application:
HVAC and refrigeration systems for machinery and accomodation rooms, short and long casings, thick metal casings up to 10mm, max. 80°C
Technical Data:
V = 1.000 - 450.000 m³/h
P = 100 - 2.800 Pa
L = 0,25 - 250 kW
|
|
Axial fan for high pressure with direct drive
Surface: hot-dip galvanized or powder coated
Options: pully belt drive, ATEX, various accessories
Sizes:
VH 310 - VH 1.250 (Ømm)
Application:
HVAC and refrigeration systems for machinery and accomodation rooms, short and long casings, thick metal casings up to 10mm, max. 80°C
Technical Data:
V = 1.000 - 150.000 m³/h
P = 300 - 2.500 Pa
L = 1 - 90 kW
|
|
Axial fan for low pressures, with direct drive
Surface: hot-dip galvanized or powder coated
Options: pully belt drive, ATEX, various accessories
Sizes:
VM 250 - VM 1600 (Ømm)
Application:
HVAC and refrigeration systems for machinery and accomodation rooms, short and long casings, thick metal casings up to 10mm, max. 80°C
Technical Data:
V = 1.000 - 200.000 m³/h
P = 100 - 1.400 Pa
L = 0.25 - 75 kW
|
|
FEATURES
Marine grade intake and discharge terminals are weatherproof. Manufactured from heavy gauge steel, vents are closable, equipped with a hand wheel.
- Accepted by Lloyd Register of Shipping
- Heavy gauge steel construction
- Flange mounted or welded installation
- Wire mesh opening protection
- Weather resistant closing mechanism
- Built to meet requirements of Regulatory Bodies
- Available for any required capacity
- Primed and/or painted finish
- Easy cleaning access
|
|
|
|
|
|
|
FEATURES
Marine grade centrifugal fans manufactured under license from Witt & Sohn are available for standard and high pressure applications in various drive configurations.
Witt & Sohn well proven expertise has established this product as one of the leaders in Marine fan technology and associated noise and vibration control.
With a standard fan design as the starting point for a given application, using the latest CAD technology the Witt design team can rapidly incorporate any requisite design modifications from standard component elements to accommodate even the most exacting fan specification.
This means that such specification criteria (eg. severity of duty; space limitations; special materials and surface treatments) - can be incorporated efficiently and at considerably less cost and lead time than a conventional one off design approach.
CONSTRUCTION
AXIAL - FLOW FANS
- Inlet Sizes - 63 to 2500 mm.
- Casing Thickness - 1,5 to 20 mm.
- Casing Pressure Types - RNN & LRZ (Low Pressure) PRZ & MRZ (Medium Pressure) HRZ (High Pressure)
- Impeller Types - Min. 6 types per casing
- Motor Frame Sizes - NEMA or IEC Standard
- Drive Types - Direct, V-belt or coupling
- Materials - Steel, Aluminum, Stainless Steel, Titanium, Special Alloys
- Surface Treatment - As axial flow fan
- Outlet Positions -See Attached
- Special Designs -Flame-proof; shock-proof; extreme temperature; gas-tight; rubberized; decontaminable; corrosion resistant, as required
|
|
CAL
For use in aggressive environments, this robust fan type delivers medium pressures. Air quantities can reach 20.8 m3/s, and pressures up to 8,500 Pa. Impeller diameters range from 630 to 1250 mm for directly coupled versions and from 315 to 1250 mm for belt-driven versions. Impeller blades are curved backwards.
|
|
CENTRIFUGAL FANS
nlet sizes 63 to 2500 mm.
Casing thickness 1,5 to 20 mm.
Casing pressure types RNN & LRZ (Low pressure). PRZ & MRZ (Medium pressure). HRZ (High pressure). SRZ (Ultra-high pressure).
Impeller types Min. 6 types per casing incl. dust impellers.
Motor frame sizes 63 to 450.
Drive types Direct, V-belt or coupling.
Materials Steel; aluminium; stainless steel; titanium; spec. alloys.
Surface treatment As axial flow fan.
Outlet positions To Eurovent.
Special designs Flame-proof; shock-proof; extreme temperature; gas-tight; rubberised; decontaminable; earth-quake proof; corrosion resistant, as required.
CCESSORIES
shaped inlets
fire dampers
protection grills
mushroom cowls
vibration attenuators
jet cowls
flexible connections
counter flanges
silencers
variable inlet vanes
inlet/outlet dampers
acoustic enclosures
insulations
monitoring instrumentation
|
|
Centrifugal fan for large air volumes and low to medium pressures.
Centrifugal fan VRQ-5E, direct drive (optional pulley belt drive)
Surface: hot-dip galvanized or powder coated
Options: pully belt drive, ATEX, various accessories
Sizes:
VRQ-5E 355 - 1.000 (Ømm)
Application:
HVAC and refrigeration systems for machinery and accomodation rooms, short and long casings, thick metal casings up to 10mm, max. 80°C
Technical Data:
V = 1.000 - 60.000 m³/h
P = 300 - 3.700 Pa
L = 0,55 - 45 kW
|
|
Centrifugal fan for large air volumes and low to medium pressures.
Centrifugal fan VRQ-12E, pulley belt drive
Surface: hot-dip galvanized or powder coated
Options: pully belt drive, ATEX, various accessories
Sizes:
VRQ-12E 250 - 1.000 (Ømm)
Application:
HVAC and refrigeration systems for machinery and accomodation rooms, short and long casings, thick metal casings up to 10mm, max. 80°C
Technical Data:
V = 1.000 - 70.000 m³/h
P = 100 - 3.700 Pa
L = 0,18 - 55 kW
|
|
FEATURES
Horizontal Type, ceiling mounted 530N Fan Coil Units provide high capacity local cooling/heating.
- Shock tested to MIL-S-901D
- High performance
- Compact Unit
- Completely prepackaged
- Units are completely tested on performance according to ARI 440-98and ASHRAE 79-91
- Factory tested
- Low weight
- Left /Right hand connections
- Electric /Hot Water Heating
- Low structure borne noise levels allow the unit to be hard mounted to the ships structure
|
|
- Portable or wall mounted low-noise fan heater
- Designed to meet applicable marine requirements
- Type approved
Specifications:
- Wall mounted or portable fan heater for marine and offshore applications.
- Corrosion resistant housing of hot zinc-plated and powder coated steel panels.
- Re-setable overheat protection.
- Low noice fan.
|
|
VMA-VMB
These air heaters are integrated units with axial flow fans and heating coils. Two versions are available, depending on the heat media being either boiler water or district heating water.
|
|
FEATURES
SMOKE DAMPERS
Class I meets UL 555S.
Class 1A smoke dampers in both vertical and horizontal mountings.
FIRE DAMPERS
For shipboard installation of A0 thru A60 fire rated divisions in both vertical and horizontal mountings. Meets FTPC Part 3, IMO Resolution A754 (18).
IMPORTANT
Type, tested and approved damper assembly does not constitute ships installation and configuration approval, which is subject to governing authorities regulations.
The fire dampers are designed for dry filtered air systems and should be subjected to the maintenance program.
|
|
Navy system 1
Navy projects can cover anything from almost merchant ship standards to specialised systems with demanding equipment and system requirements. Each project is individually evaluated with regard to necessary custom solutions.
|
|
NovPac-R
The self-contained air handling units type NovPac-R are compact and designed for supplying air conditioning in rooms such as engine control rooms, switchboard rooms, workshops etc.
|
|
|
|
|
|
|
EUMM and EMAA are modern, high specification Air Handling Unit ranges with all of the functional sections needed to meet any air handling requirement.
The frame members and solid corner pieces form a sturdy framework.
EUMM is a modular unit offering flexibility of function, size and process while the EMAA is a compact unit based on the same design platform aimed specifically at the needs of the modern cruise liner.
That means we control quality and performance of the entire unit to ensure problem free installation and service.
Some of the main features of our Air handling units:
- Sturdy framework with box-section steel frame members.
- Solid composite material or aluminium, powder-coated corner pieces with no sharp edges.
- 50 mm thick double-skin, flush-fitting panels.
- Non-hygroscopic, rigid sheet, mineral wool insulation with a density of 50 kg/m3.
- Fully enclosed panels.
- Purpose designed coil connection seals.
- Fully dismountable casing.
- Multi-section blocks to reduce site assembly time.
- Corrosion resistant components designed for the maritime environment.
- Stainless steel casing available as a standard alternative.
- Painted casing available as an option.
- Taylor made marine functions.
|
|
GT Centrimaster belt driven
These single inlet, centrifugal fan series consists of centrifugal fans, belt driven, available with two types of impeller:
-Impeller with forward curved blades made of galvanized sheet steel.
- Impeller with backward-curved blades, made of sheet steel and welded, coated with epoxy powder. The fans are also available in a spark-proof version with the inlet cone made of brass.
|
|
Air cooled condensing units, special designed for marine application.
Mainly used for additional cooling systems for navigating bridges.
Innovative special developed KLH Refrigeration units.
Cooling capacity 5 - 20 KW (17000-68000 BTU/h).
|
|
|
The electric marine heater type HWG is used to heat washrooms, showers, dry areas and stores. Its slim, upright design make it specially suitable for installation in areas where space is limited.
|
|
Living quarters, bathrooms, stores and engine rooms
Wall mounting
Incorporated thermostat with on/ off switch
Safety temperature limiter
|
|
The electric marine heaters of the HU and UE series meet the requirements of all well known classification societies.
Depending on the locality there is a choice between the on-the-wall type HU and the recessed type UE.
|
|
Wall mounted or portable fan heater for marine and offshore applications.
Corrosion resistant housing of hot zinc-plated and powder coated steel panels.
Re-setable overheat protection.
Low noise fan.
|
|
This is a single duct air supply unit designed for ceiling mounting above the false ceiling. Intended for climate control in spaces on board ships, such as cabins, offices, messes, utility spaces etc.
- Provides good thermal comfort.
- Offers individual temperature control of both supply air temperature and air flow.
- Available for manual or automatic control by means of a pneumatic or electrical actuator.
- Offers quick and simple installation and commissioning.
- The internal insulation satisfies the criteria of IMO Resolution for classification as non-combustible.
- Conforms to the provisions of IMO Resolution for false ceilings with fire resistance rating B15.
- Satisfies the vibration and temperature requirements specified by Det Norske Veritas.
|
|
|
Fan coil units can be applied when cooling or heating is required. This unit can be easily installed in the compartment without being entirely visible. It is possible to install several in the same compartment. This way the capacity is increased or can be dispersed without any problem. Included with this system are all standard items that are required for mounting and installing the unit. Fan coil units can be perfectly combined with all our existing systems.
|
|
|
Tailor made Accommodation Heaters provide the optimal indoor climate for personel and equipment. The heaters are provided and designed according to Customers request.
|
|
|
|