|
|
The Contour Matrix Gas Detectors are the product of continuing research and development which BEP Marine Ltd devotes to their product range. The BEP Detectors use microprocessor control to ensure correct sensor sensitivity. The Detectors have the capability to control two sensors which detect both LPG and Petrol, with visual and audible alarms. There is a test switch to check operation of sensors with indicators for fault detection.
Features:
- Operating Voltage 10 to 32 Volts DC
- Self testing capability
- Microprocessor control
- Provision for external alarm
- Automatic shut-off solenoid control with pulse and hold circuit for low power draw (600-GDL only).
- Provision for bilge blower
- Dual sensor capability
- For remote alarm operation use part no. 54-27C4
|
|
The Contour Matrix Gas Detectors are the product of continuing research and development which BEP Marine Ltd devotes to their product range. The BEP Detectors use microprocessor control to ensure correct sensor sensitivity. The Detectors have the capability to control two sensors which detect both LPG and Petrol, with visual and audible alarms. There is a test switch to check operation of sensors with indicators for fault detection.
Features:
- Operating Voltage 10 to 32 Volts DC
- Self testing capability
- Microprocessor control
- Provision for external alarm
- Automatic shut-off solenoid control with pulse and hold circuit for low power draw (600-GDL only).
- Provision for bilge blower
- Dual sensor capability
- For remote alarm operation use part no. 54-27C4
|
|
Refrigerant Gas Leak Detection
MM2000® is an intelligent addressable gas detection system designed to provide refrigerant gas detection on ships under MARPOL Annex VI Regulation 12-Ozone Depleting Substances, 5.5 Leak Monitoring Systems.
Refrigerant gases are monitored continuously by fixed gas sensors installed in the vicinity of refrigeration and air conditioning machinery such as compressor room refrigerant leak detection. Class societies advocate the use of fixed leak detection systems for environmental protection (e.g. Lloyds EP Notation) The MM2000® system operates on a single 4-core cable having the capacity to monitor from 1 to 32 addressable sensors.
The control system provides local indication of the measured parameters and alarm conditions together with relay contacts to shut down air conditioning or refrigeration plants as necessary.
- TYPE APPROVED
- LOOP SENSOR CABLE FOR LOW COST INSTALLATION
- NO MOVING PARTS
- CONTINUOUS MONITORING OF ALL LOCATIONS
|
|
Consilium offers the world’s only true continuous measuring NOX, SO2 and CO2 analysing equipment for marine applications.
Salwico NOx & SO2 Analyzing System
The Salwico Emission Monitoring System is the world’s only true continuous measuring NOx, SO2 and CO2 analysing equipment for marine applications. The system, fully type approved by Lloyds Register (certificate number 07/00043), measures emissions of Oxides of Nitrogen (NOx), Sulphur Dioxide (SO2) and the greenhouse gas CO2 from the engine exhaust of marine diesel engines.
Salwico NOx & SO2 Analyzing System is a continuous measuring and analysing equipment for marine applications. Unlike other competitors non-compliant solutions based on electrochemical sensor technology our analyzing technology is based on the regulatory chemiluminescent principle as stated in the “Marpol Annex VI NOx Technical Code”
|
|
Accommodation Air Conditioning Inlet Gas Detection
The new fifth edition of ISGOTT now identifies the advantage of fitting flammable gas detection at accommodation air conditioning inlet. MM2000® is an intelligent addressable gas detection system that is ideally suited to this duty with duct mounted flammable gas detectors simply mounted on the inlet and the control panel located in the cargo control room (CCR).
The addressable sensors are installed on a single four-core loop cable that saves installation costs when multiple inlets are to be monitored, for monitoring general accommodation areas and hydrogen sulphide / hydrocarbon gas detection in the cargo pump room.
In total, the system can monitor 32 individual gas detectors meaning most applications can be serviced by one compact MM2000® control panel.
|
|
|
|
|
|
|
Ballast Tank Gas Detection & Void Space Gas Detection System
MM5001® is a major advancement in marine gas detector technology for monitoring ballast tank gas detection and void space gas detection onboard ships. The system comprises of a central control cabinet with a touch screen panel to display information and alarm status. Within the cabinet is the main PLC controller, analysing equipment plus a pre-sampling circuit as standard. A calibration free, high performance infrared sensor provides the ultimate in reliable flammable gas analysis.
The PLC is extremely reliable with an MTBF of 20 years plus. The gas analyser does not require re-calibration and the pre-purge significantly reduces sampling cycle times.
MM5001® is fully compliant with IACS UR F43, Exxon MOBIL MESC 2002 - Term charter, Chapter 8 & EMSA regulations for double hulled tankers.
- CALIBRATION FREE, HIGH PERFORMANCE IR SENSORS
- FULLY FLEXIBLE PLC CONTROLLER
- PROGRAMMABLE OPERATION DURING BALLASTING
- INTEGRATED SYSTEM FOR BOTH GAS SAMPLING & FIXED POINT SENSORS
|
|
Gas Detection, Fixed Systems, Pump Room & Tank Monitoring
Analox manufactures a range of saftey equipment for toxic, flammable and inert gases. A number of portable and fixed analysers are available for use in applications such as pump rooms, tank monitoring, boiler houses, petrochemical installations, water treatment plants and laboratories.
|
|
Biosystems introduces its smallest confined space detector — the MultiPro.™
The MultiPro offers real time readings for up to 4 gases, true one-button operation (including calibration), and a built-in event logger capable of storing information for 20 events including sensor type, max and average readings, time and duration. It´s available with either a Li-Ion or an Alkaline battery pack and offers run times up to 22 hours. For remote sampling, both manual and motorized sample draw kits are available.
|
|
In developing the Salwico GS3000 we have used the experiences and hardware from our proven and trusted fire detection system, the Salwico CS3000 and adapted these to gas detection requirements found in offshore applications, onboard LNG carriers and other demanding installations.
Un-rivalled still today the Salwico GS3000 is by far the most dependable loop-configured analogue addressable gas detection system in the world and it offers all the features and functions of the larger Fire Detection System and then we added some more to cover for the gas detection needs specifically.
|
|
Autronica Fire and Security has developed the world's first interactive-addressable system for integrated fire and gas detection: AutroSafe Integrated Fire and Gas Detection System (IFG), the only integrated fire and gas detection system that is approved according to IEC 61508 Safety Integrity Level 2 (SIL2).
AutroSafe IFG has been developed in close collaboration with the petrochemical, oil and gas industry. AutroSafe IFG is designed to comply with present and future standards, including EN 54, and is approved by many international standards organizations
|
|
Refrigerant Gas Leak Detection
MM2000® is an intelligent addressable gas detection system designed to provide refrigerant gas detection on ships under MARPOL Annex VI Regulation 12-Ozone Depleting Substances, 5.5 Leak Monitoring Systems.
Refrigerant gases are monitored continuously by fixed gas sensors installed in the vicinity of refrigeration and air conditioning machinery such as compressor room refrigerant leak detection. Class societies advocate the use of fixed leak detection systems for environmental protection (e.g. Lloyds EP Notation) The MM2000® system operates on a single 4-core cable having the capacity to monitor from 1 to 32 addressable sensors.
The control system provides local indication of the measured parameters and alarm conditions together with relay contacts to shut down air conditioning or refrigeration plants as necessary.
- TYPE APPROVED
- LOOP SENSOR CABLE FOR LOW COST INSTALLATION
- NO MOVING PARTS
- CONTINUOUS MONITORING OF ALL LOCATIONS
|
|
Consilium offers the world’s only true continuous measuring NOX, SO2 and CO2 analysing equipment for marine applications.
Salwico NOx & SO2 Analyzing System
The Salwico Emission Monitoring System is the world’s only true continuous measuring NOx, SO2 and CO2 analysing equipment for marine applications. The system, fully type approved by Lloyds Register (certificate number 07/00043), measures emissions of Oxides of Nitrogen (NOx), Sulphur Dioxide (SO2) and the greenhouse gas CO2 from the engine exhaust of marine diesel engines.
Salwico NOx & SO2 Analyzing System is a continuous measuring and analysing equipment for marine applications. Unlike other competitors non-compliant solutions based on electrochemical sensor technology our analyzing technology is based on the regulatory chemiluminescent principle as stated in the “Marpol Annex VI NOx Technical Code”
|
|
Accommodation Air Conditioning Inlet Gas Detection
The new fifth edition of ISGOTT now identifies the advantage of fitting flammable gas detection at accommodation air conditioning inlet. MM2000® is an intelligent addressable gas detection system that is ideally suited to this duty with duct mounted flammable gas detectors simply mounted on the inlet and the control panel located in the cargo control room (CCR).
The addressable sensors are installed on a single four-core loop cable that saves installation costs when multiple inlets are to be monitored, for monitoring general accommodation areas and hydrogen sulphide / hydrocarbon gas detection in the cargo pump room.
In total, the system can monitor 32 individual gas detectors meaning most applications can be serviced by one compact MM2000® control panel.
|
|
|
|
|
|
|
Ballast Tank Gas Detection & Void Space Gas Detection System
MM5001® is a major advancement in marine gas detector technology for monitoring ballast tank gas detection and void space gas detection onboard ships. The system comprises of a central control cabinet with a touch screen panel to display information and alarm status. Within the cabinet is the main PLC controller, analysing equipment plus a pre-sampling circuit as standard. A calibration free, high performance infrared sensor provides the ultimate in reliable flammable gas analysis.
The PLC is extremely reliable with an MTBF of 20 years plus. The gas analyser does not require re-calibration and the pre-purge significantly reduces sampling cycle times.
MM5001® is fully compliant with IACS UR F43, Exxon MOBIL MESC 2002 - Term charter, Chapter 8 & EMSA regulations for double hulled tankers.
- CALIBRATION FREE, HIGH PERFORMANCE IR SENSORS
- FULLY FLEXIBLE PLC CONTROLLER
- PROGRAMMABLE OPERATION DURING BALLASTING
- INTEGRATED SYSTEM FOR BOTH GAS SAMPLING & FIXED POINT SENSORS
|
|
Gas Detection, Fixed Systems, Pump Room & Tank Monitoring
Analox manufactures a range of saftey equipment for toxic, flammable and inert gases. A number of portable and fixed analysers are available for use in applications such as pump rooms, tank monitoring, boiler houses, petrochemical installations, water treatment plants and laboratories.
|
|
Biosystems introduces its smallest confined space detector — the MultiPro.™
The MultiPro offers real time readings for up to 4 gases, true one-button operation (including calibration), and a built-in event logger capable of storing information for 20 events including sensor type, max and average readings, time and duration. It´s available with either a Li-Ion or an Alkaline battery pack and offers run times up to 22 hours. For remote sampling, both manual and motorized sample draw kits are available.
|
|
|
|
|
|
|
The G1000 Smoke Density Monitor is used to check smoke emissions from all kinds of combustion such as diesel engines, incinerators, and boilers.
The G1000 Smoke Density Monitor is a particular robust system that is well suited to resist heat and vibrations in and around smoke stacks. Our patented technology removes the light source from the smoke stack contrary to traditional opacity monitors used on the land side.
Furthermore, the G1000 Smoke Density Monitor is easy to keep clean with purge air and easy to maintain. This robustness is combined with high flexibility which means that the G1000 Smoke Density Monitor can be installed in very diverse settings and be adapted for your special needs.
Port authorities and regional authorities around the world – but especially in North America – are to increasing degrees regulating emissions from shipsas well as from industrial plants. Although legislation is varying, regulations in North America would typically rule that ships may not emit smoke with an opacity of more than 20% for more than 3 minutes. A similar limit is set for shipboard incinerators by IMO.
|
|
|
|