ous let us not approve the use of this blower-extractor to feed in air the compartment engine. A marine engine must normally aspire air sufficient, if surfaces of ventilation are sufficient.
Placé on the suction duct of air of the engine, the aspiration of the thermal engine can be such as the electric motor packs and roasts. The goal of this blower is to extract the hot air after stop from the engine.
* "explosion-proof Protection"
* Meets the standards ISO 9097
* Available in 12 Volt (8 Amp.) or 24 Volt (4 Amp.)
* Capacity: Ca air volume displacement 12,2 m3 minute to 12 Volt D.C
Static pressure: 32 mm H20. Ca 12.5 mVminute with 24 Volt.
Static pressure: 36 mm H20.
* On partition, for pipe O 178 mm int (see page 36).
|
|
ous let us not approve the use of this blower-extractor to feed in air the compartment engine. A marine engine must normally aspire air sufficient, if surfaces of ventilation are sufficient.
Placé on the suction duct of air of the engine, the aspiration of the thermal engine can be such as the electric motor packs and roasts. The goal of this blower is to extract the hot air after stop from the engine.
* Device protected against
lighting (ISO 8846).
* Meets the standards
ISO 9097
* Harness Delrin.
* Capacity 4 m3 per minute.
* static pressure: 57 mm H2O
* Especially for kitchens,
toilets and compartments
engine.
* Deliverable in 12 or 24 Volt.
* On sheath 76 mm 0 int is connected. (see page 115).
* 12 V - 8 A./24 V - 4 A.
|
|
ous let us not approve the use of this blower-extractor to feed in air the compartment engine. A marine engine must normally aspire air sufficient, if surfaces of ventilation are sufficient.
Placé on the suction duct of air of the engine, the aspiration of the thermal engine can be such as the electric motor packs and roasts. The goal of this blower is to extract the hot air after stop from the engine.
For installation inside a pipe of extraction with dia. int. of 76 mm).
Device protected from lighting (ISO 8846).
Meets the standards ISO 9097
Capacity 4 m3 per minute.
Static pressure 36 mm H2O.
Available in 12 V - 2.8 Amp. maximum.
Is appropriate for pipe of extraction dia. 78 Mr.
Pipe which can be connected, for example, with the ventilators.
|
|
|
Gallinea fans are the outcome of a thorough analysis of all the requirements of clients operating in the nautical field. Each machine is developed starting from the actual conditions of use, this is possible thanks to control devices and test benches where the fans are tested. We can therefore assure our customers not only the provision of equipment but also technical advice that they may need to optimize the ventilation system in the engine room; for example, the lost pressure in the local vents.
|
|
|
|